CGQBX - ANTIMONY ICP STANDARD, ICP101N

  • MSDS: CGQBX
  • Manufacturer: EM SCIENCE
  • Product Name: ANTIMONY ICP STANDARD, ICP101N
  • National Stock Number: 6810-00N083312
Product Identification

Product ID:ANTIMONY ICP STANDARD, ICP101N
MSDS Date:06/05/1997
FSC:6810
NIIN:00N083312
MSDS Number: CGQBX

Responsible Party
EM SCIENCE
480 DEMOCRAT RD
GIBBSTOWN, NJ 08027
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 609-354-9200

Cage: DO242

Contractor
EM SCIENCE
70 GIBBSTOWN, NJ 08927 US

Telephone: 800-424-9300 (CHEMTREC)

Cage: DO242

Ingredients

ANTIMONY (SARA 313) (CERCLA)

CAS: 7440-36-0

RTECS: CC4025000

Fraction By Weight: 0.1-1%

OSHA PEL 0.5 MG/M3

ACGIH TLV: 0.5 MG (SB)/M3

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


NITRIC ACID (SARA 302/313) (CERCLA)

CAS: 7697-37-2

RTECS: QU5775000

Fraction By Weight: 2-5%

OSHA PEL 2 PPM

ACGIH TLV: 2 PPM/4 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 94-95%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRITATING TO EYES AND MUCOUS
MEMBRANES. MAY CAUSE EYE INJURY. MAY BE HARMFUL IF SWALLOWED. MAY
BE IRRITATING ON CONTACT WITH SKIN, EYES OR MUCOUS MEMBRANES. VAPOR
IRRITATING TO EYES AND RESPIR ATORY PASSAGES. CHRONIC: NONE
SPECIFIEDBY MANUFACTURER.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:RESPIRATORY CONDITIONS.

First Aid

First Aid:GET MEDICAL ASSISTANCE FOR ALL CASES OF OVEREXPOSURE. SKIN:
IMMEDIATELY FLUSH THOROUGHLY WITH LARGE AMOUNTS OF WATER. EYES:
IMMEDIATELY FLUSH THOROUGHLY WITH WATER FOR AT LEAST 15 MINUTES.
INHALATION: REMOVE TO FRESH AIR; GIVE ARTIFICIAL RESPIRATION IF
BREATHING HAS STOPPED. INGESTION: GET IMMEDIATE MEDICAL ATTENTION;
IF CONSCIOUS, GIVE WATER FREELY.

Fire Fighting

Flash Point:NON-COMBUSTIBLE
Extinguishing Media:USE ANY SUITABLE FOR ADJACENT MATERIAL.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCES TOXIC
FUMES.

Accidental Release

Spill Release Procedures:EVACUATE AREA OF ALL UNNEC PERS. WEAR SUITABLE
PROT EQUIP. ELIM ANY IGNIT SOURCES UNTIL AREA IS DETERMINED TO BE
FREE FROM EXPLO/FIRE HAZS. CONTAIN RELEASE & ELIM ITS SOURCE, IF
THIS CAN BE DONE W/OUT RISK. TAKE UP & CONTAINERIZE FOR PROPER
(SUP DAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED. STORE AT
CONTROLLED ROOM TEMPERATURE. DO NOT BREATHE VAPOR. DO NOT GET IN
EYES, ON SKIN, OR ON CLOTHING.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:MATERIAL SHOULD BE HANDLED OR TRANSFERRED IN AN APPROVED
FUME HOOD OR WITH ADEQUATE VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. DO NOT TAKE
INTERNALLY.
Supplemental Safety and Health
SPILL PROC: DISP. COMPLY W/FED, STATE, & LOC REGS.

Chemical Properties

Solubility in Water:SOLUBLE
Appearance and Odor:LIQUID

Stability

Stability Indicator/Materials to Avoid:YES
NONE INDICATED.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:OXIDES OF NITROGEN.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.